Project Overview
Huatai supplied a complete on-site nitrogen generation system for a new specialty plant oils and derivatives project in Guang’an, Sichuan.
The project forms part of Huatai’s nitrogen generation solutions for chemical production, configured around the required nitrogen purity, flow, pressure and production schedule.
The system was configured for two nitrogen purity requirements—99.5% and 97%—with variable flow output based on the selected operating configuration and a delivery pressure of 0.5 MPa.
The delivered package integrates air compression, compressed-air treatment, nitrogen generation, gas storage and Siemens PLC control. The system has been delivered and is awaiting startup alongside the customer’s new production facilities.
- Customer: Guang’an Dayou Chemical / Zhengxin Chemical (Sichuan) Co., Ltd.
- Project: Specialty Plant Oils and Derivatives Project
- Industry: Specialty Oils and Chemical Processing
- Location: Guang’an, Sichuan, China
- Gas: Nitrogen
- Nitrogen Purity: 99.5% and 97%
- Nitrogen Flow: Variable based on the selected operating configuration
- Delivery Pressure: 0.5 MPa
- Nitrogen Generators: KFD295-100 and KFD97-150
- Installation: Fixed indoor installation
- Control System: Siemens PLC
- Operating Requirement: Continuous nitrogen supply
- Project Status: Delivered; awaiting startup of the new production facilities
Need some help?
If you are unsure exactly what you need,
get in touch and we can help identify your requirements.
What Nitrogen Supply Did the Specialty Plant Oils Project Require?
The customer required an on-site nitrogen supply for a new specialty plant oils and derivatives project. With no existing nitrogen source available for the new production facilities, the project required a complete nitrogen generation station rather than a standalone nitrogen generator.| Selection Factor | Project Information |
| Application | Natural Gas Extraction Process |
| Nitrogen Purity | ≥99.9% |
| Nitrogen Flow | Pending Final Confirmation |
| Delivery Pressure | Pending Final Confirmation |
| Operating Mode | Continuous |
| Installation Type | Fixed System |
| Control System | Siemens PLC |
| Power Supply | 380/220 V |
Why Did the Project Require Two Nitrogen Purity Levels?

How Was the Dual-Purity Nitrogen Generation System Configured?
Huatai supplied a complete on-site nitrogen generation system covering compressed-air production, air treatment, nitrogen separation, gas storage and system control. The configuration included KFD295-100 and KFD97-150 nitrogen generators for the specified 99.5% and 97% nitrogen supply conditions.
The nitrogen-generation section include industrial nitrogen generators configured around the project’s 99.5% and 97% nitrogen requirements.
System Components
- Three air compressors
- Refrigerated air dryer
- Compressed-air filtration system
- KFD295-100 nitrogen generator
- KFD97-150 nitrogen generator
- Gas receiver tanks
- Siemens PLC control system
- Nitrogen Generation Process
Air compressors → Refrigerated air dryer → Compressed-air filtration → Nitrogen generators → Gas receiver tanks → Plant nitrogen distribution
Compressed air is produced, dried and filtered before entering the nitrogen generators. The generated nitrogen then passes to the applicable receiver tanks before being delivered to the plant’s nitrogen distribution system.
The final storage and distribution arrangement follows the project piping design. The two nitrogen purity levels are therefore shown as separate supply conditions without assuming whether they share receiver tanks or distribution pipelines.
Huatai’s on-site nitrogen generation solutions can integrate compressed-air supply, air treatment, nitrogen generation, gas storage and system control according to the requirements of each project.
How Does the Four-Tower System Adjust Nitrogen Flow?
How Does the Three-Compressor Configuration Support Variable Demand?
How Are Nitrogen Purity, Flow and Pressure Controlled?
Nitrogen Purity
Nitrogen Flow
Delivery Pressure
How Is the Complete Nitrogen Station Controlled?

Automated Equipment and Process Control
Depending on the final control configuration, the PLC can manage:
-
- Nitrogen generator operating sequences
- Valve switching
- Applicable equipment start and stop control
- Load-based equipment coordination
Operating Monitoring and Alarm Display
The PLC interface can display:
-
-
-
- Equipment operating status
- Process parameters
- Alarm indications
-
-
What Was Considered for Indoor Installation at the Chemical Plant?
The nitrogen station was configured for fixed installation in an indoor, ventilated area of the plant. The equipment layout needed to accommodate three air compressors, air-treatment equipment, two nitrogen generator configurations and gas receiver tanks while maintaining access for operation, inspection and routine maintenance.
The installation planning considered:
-
-
-
- Indoor ventilation conditions
- Compressor air intake and heat-dissipation clearance
- Maintenance access for the refrigerated air dryer and filters
- Access to nitrogen generator valves, instruments and filter elements
- Receiver tank positioning and pipeline connections
- 380/220 V electrical supply conditions
- Equipment foundations and drainage
- Plant nitrogen pipeline routing
- Applicable local pressure-vessel and chemical-plant requirements
-
-
The installation area and electrical configuration must be reviewed against the customer’s confirmed site classification. This project should not be described as an explosion-proof nitrogen station or as suitable for hazardous areas unless the applicable protection rating has been verified.